Injector Steps: Performs each movement of the sampling sequence under manual control.Thermostat Test: Evaluates the cooling and heating performance of the two Peltier elements.G1316A Column Compartment Diagnostic Tests: Leak Test: The leak test is a built-in troubleshooting designed to demonstrate the leak-tightness of the pump.Pressure Test: The pressure test is a quick, built-in test designed to demonstrate the pressure tightness (up to 400 bar) of the system.Baseline Noise Test: The test measures the amount of baseline noise drift identified by the detector.Wavelength Intensity Test: The test confirms the accuracy of wavelengths measured.Lamp Intensity Test: The test verifies functionality of the UV lamp at various wavelengths.The spectrum is evaluated for peaks at different wavelengths. Holmium Oxide Test: The test measures the Holmium spectrum from the built-in Holmium filter.Dark Current Test: The test measures the dark current from the detector optic.Filter Test: The test moves the filter into the light path and measures the relative absorbance in the filter position.G1315B Diode Array Detector & G1321A Fluorescence Detector Diagnostic Tests:
The HPLC System features extensive diagnostics with compatible data analysis software for on-site and remote trouble-shooting.Īll of our equipment is fully tested to perform at factory specifications before being shipped.īelow is a List of Diagnostic Tests Performed On This System The unit can be operated with a hand-held controller or computer running Clarity software.
The FD's spectral information can be used for rapid method optimization and verification of separation quality. This easy-to-use detector provides quantitative data and fluorescence spectra from a single run. The Agilent 1100 Fluorescence Detector brings high-sensitivity and selection through simultaneous multi-wavelength detection. Slit settings can be stored and reported from 1 – 16 nm with raw data for GLP traceability. The programmable slit helps you explore the spectral landscape for faster sample characterization, ensuring higher sensitivity or lower baseline noise as necessary on the 1100. This detector features superb illumination using combined deuterium and tungsten lamps for the highest intensity and lowest detection limit from 190 to 950 nm, 1024 diodes and 1-nm slit for highest spectral resolution. The Agilent 1100’s temperature management system ensures optimum baseline stability-even under rough ambient conditions. The VWD and diode array detectors allow for automated wavelength verification for performance tracking. The Agilent 1100 Diode Array Detector verifies separation quality with peak purity, multiple signals, and spectral libraries during your analytical quantification, offering an extended wavelength range with the highest sensitivity. The HPLC System’s vacuum degasser ensures reduced operating costs without the use of helium and optimum instrument performance.
It also features a high-speed proportioning valve and a pre-configured degasser, which allow convenient low-pressure mixing and a large solvent choice flexibility. This electronically activated inlet valve runs synchronous to the pistons to eliminate vapor formation in volatile solvent, making the Agilent 1100 both remarkably easy-to-use and maintenance-free. The system’s optimized design using a quaternary pump allows variable stroke volumes for stable solvent flow. The Agilent 1100 HPLC System guarantees the most efficient mixing and pulse-free solvent delivery for consistently fast and accurate results. Agilent 1100 HPLC System with Diode Array Detector & Fluorescence Detector